Riva2 600 600HL Conventional Flue Installation Instructions
29
1. Commissioning
1.1 Check the flame picture, log layout.
1.2 Check the gas pressure.
1.3 Close all door and windows in the room.
1.4 Ignite the appliance and operate on maximum for 5 minutes.
1.5 Position a lighted smoke match just inside the draught
diverter opening (under the canopy) and check all smoke is
drawn in along the opening, see Diagram 1.
1
Canopy
If there is any doubt:
1.6 Run the appliance for a further 10 minutes and repeat the
test.
If there are any extractor fans in the room or adjacent
rooms, the test must be repeated with the fans running on
maximum.
IF SPILLAGE PERSISTS, DISCONNECT THE
APPLIANCE AND SEEK EXPERT ADVICE.
For future reference, record the installation details on the
Commissioning Sheet on page 3.
1.7 Complete the Commissioning Checklist at the front of this
manual covering:
— Thermocouple soundness checks.
This is to include ensuring the thermocouple is secure on
the pilot bracket assembly, lead connection and integrity.
— Flue checks
— Gas checks
— Log/fuel effect layout - flame picture
For working pressure test, refer to Installation Instructions
Section 7.
1.8 Upon completion of the commissioning and testing of the
installation and correct operation of the appliance, the
installer must instruct the user how to operate the
appliance.
1.9 Guide the user through the User Instructions paying
particular attention to:
a) Regular servicing (Section 9 of the User Instructions).
b) Ventilation (Section 10 of the User Instructions) - point out
the ventilation positions where applicable.
c) Hot surfaces (Section 12 of the User Instructions).
d) How the appliance works with the remote control handset
and the modes of operation (Section 2 of the User
Instructions).
e) How to change settings in the auto mode and program
modes of operation.
f) What to do if the appliance fails to operate (Section 13 of
the User Instructions).
Reprogramming handset/Control box
To access the control box see Servicing Instructions,
Section 4 - Main Burner.
— Press and hold the reset button on the control box until
you hear two signals. After the second longer signal:
— Release the reset button and within 20 seconds:
— Press the DOWN button on the handset until you hear
two additional short signals confirming the new code is
set.
If there is a single long signal the code learning sequence
has failed or the wiring is incorrect.