Riva2 600 600HL Conventional Flue Installation Instructions

23
Installation Instructions
7. Fitting the Burner Assembly
7.1 Ensure there is enough length on the Inlet Pipe to reach the
front of the rebox.
7.2 Attach the Inlet Pipe to the Compression Elbow and secure
in the bracket at the front of the rebox, see Diagram 30.
30
Detail A
(View from inside rebox)
A
7.3 PURGE THE SUPPLY PIPE. This is essential to expel any
debris that may block the gas controls.
8. Fitting the Burner Assembly
8.1 Angle the front of the burner tray forwards with the right
hand side slightly forwards and lower into the appliance, see
Diagram 31.
31
8.2 Slide the left hand side forward ensuring the burner tray
and splitter plate ts around the mounting bracket, see
Diagram 32.
32
8.3 Feed the pipe from the Burner Assembly into the
Compression Elbow as the engine is tted, see Diagram 33.
33
9. Gas Soundness Pressure Check
9.1 Connect a suitable pressure gauge to the test point located
on the inlet fitting and turn the gas supply on. Light the
appliance and check all gas joints for possible leaks. Turn
the appliance to maximum and check that the supply
pressure is as stated on the databadge. Turn the gas off
and replace the test point screw, turn the gas on and check
the test point for leaks.
34
Check the function of the handset, if there is no
communication between the remote control and the
appliance, see Commissioning Section.