Riva2 600 600HL Conventional Flue Installation Instructions
22
Installation Instructions
6b.4 Site the appliance and decide on flue requirements.
6b.5 Prepare the flue connection using the chosen method
described in Section 2 ensuring that distances to
combustible materials are maintained at all times.
Connect the flue and install the appliance into the aperture.
At the same time ensure that the elbow and supply pipe
passes through the silicon panel at the back of the
appliance.
Do not secure the appliance at this time.
6b.6 Fit non-combustible board to the studwork around the
aperture. This should extend a minimum of 400mm above
the appliance and at least 150mm to the sides of the
appliance, see Diagram 25 and Diagram 26.
25
Min 400mm
Bottom of Appliance
Min 150mm
Min 150mm
26
Non-combustible
Board
Appliance
Outer
Casing
Appliance
Edge
Combustible
Stud
Metal Stud
Heat resistant Plaster
Appliance Flange
Ensure the clearances are maintained, see Diagram 15.
6b.7 Apply plasterboard to the remainder of the studwork and
plaster the front face of the board.
6b.8 Secure the appliance to the non-combustible board through
the 6 fixing holes, using the anchor fixings provided, see
Diagram 27 & 28.
27
28
Appliance Edge
Appliance Flange
Non-combustible
Board
Fixings
6b.9 Attach the Compression Elbow to the inlet pipe and secure
to the bracket on the inside of the firebox, see Section 7.
6b.10 Install the decorative front referring to separate installation
instructions.
To finish installation see 6.6.
To Finish the Installation
After commissioning:
6.6 Finish the sides of the chimney breast, see Diagram 29.
29
6.7 A removable access hatch must be left in the side of the
chimney breast for future servicing and inspection of the
appliance.