Installation Instructions
20
Appliance Edge
Appliance Flange
Non-combustible
Board
Fixings
6a.10 Attach the Compression Elbow to the inlet pipe and secure
to the bracket on the inside of the firebox, see Section 7.
6a.11 Fit non-combustible board to the board around the
appliance, see Diagram 21. Ensure distances to
combustibles are observed, see Diagram 15.
21
Combustible
Stud
Non-combustible
Board
Appliance
Outer Casing
Appliance
Edge
Heat Resistant Plaster
Appliance
Flange
NOTE: If metal studwork is used, there is no need to fit
non-combustible board to the inner face of the construction,
see Diagram 22.
22
Metal Studs
Non-combustible
Board
Appliance
Outer Casing
Appliance
Edge
Plasterboard
Heat Resistant
Plaster
Appliance
Flange
Plaster
6a.12 Apply plasterboard to the remainder of the first layer of
plasterboard.
6a.13 Apply a heat resistant plaster around the appliance, see
Diagram 22. Ensure distances to combustibles are
observed, see Diagram 15.
6a.14 Apply a plaster finish to the remaining plasterboard.
To finish installation see 6.6.
6b. Installation with a
Decorative Front
IMPORTANT: BEFORE THE INSTALLATION OF
THE DECORATIVE FRONT ENSURE THAT THE
WALL ABOVE AND TO THE SIDES OF THE
APPLIANCE IS SUITABLY CONSTRUCTED FOR
THE FIXINGS TO SUPPORT THE WEIGHT OF THE
FRONT. IF THE WALL IS CONSTRUCTED FROM
PLASTERBOARD OR SIMILAR, IT IS ESSENTIAL
THAT BATTERNS ARE LOCATED TO THE SIDES
OF THE APPLIANCE IN THE FIXING AREA TO
PROVIDE STRENGTH TO THE FIXINGS. SEE
DIAGRAM 23.
6b.1 When constructing a studwork installation it is essential to
observe the clearances to combustibles but make provision
for the frame fixings, see Diagram 23.
23
This diagram shows the minimum clearance position when installing
the appliance into studwork - it is vital to ensure the batterning is
wide enough to accommodate the fixings for the front.
A
Distance between front fixings:
FRAME OPTION A
Icon XS 759
Evoke XS 727
Verve XS 759
6b.2 Build the studwork chimney breast and enclosures to the
desired size to include the protected platform at the required
height.
6b.3 Line the aperture for the appliance with 12mm thick
non-combustible material as shown, see Diagram 24.
24