Riva2 600 600HL Conventional Flue Installation Instructions

19
Installation Instructions
5a.9 Fit plasterboard to the remaining of the chimney breast front.
5a.10 Apply a heat resistant plaster around the appliance using
the distance to combustibles detailed in Diagram 13.
5a.11 Apply a plaster finish to remaining chimney breast front.
5b. Installation with a
Decorative Front
5b.1 Fix the self adhesive foam seal around the back of the fixing
flange of the appliance.
5b.2 Prepare the flue connection using the chosen method
described in Section 2.
5b.3 Connect the flue and install the appliance into the aperture.
At the same time ensure that the elbow and supply pipe
passes through the silicon panel at the back of the
appliance.
5b.4 Secure the appliance through the 6 fixing holes using the
screws provided, see Diagram 12.
5b.5 Attach the Compression Elbow to the inlet pipe and secure
to the bracket on the inside of the firebox, see Section 7.
5b.6 The appliance flange should sit flush to the brickwork and
the edge should sit proud of the wall, see Diagram 14.
14
Appliance
Edge
Masonry
Brickwork
Appliance
Outer Casing
Heat Resistant
Plaster
Appliance Flange
5b.7 The subframe for the decorative front can now be fitted by
following the instructions supplied with the Front.
NOTE: THE SUBFRAME MUST SIT FLUSH TO THE
WALL LEVEL WITH THE APPLIANCE FLANGE.
6. Studwork Installation
6.1 DISTANCE TO COMBUSTIBLE MATERIAL
COMBUSTIBLE PARTS OF THE STUDWORK MUST BE
KEPT BEYOND THE MINIMUM DIMENSIONS SHOWN IN
DIAGRAM 15.
PROTECT THE NEAREST STUDWORK WITH
NON-COMBUSTIBLE MATERIAL AND MAINTAIN THESE
DIMENSIONS AT ALL TIMES, SEE DIAGRAM 15.
MINIMUM
COMBUSTIBLE
MATERIAL
CLEARANCES
15
400mm
* see note
225mm
12mm
* see note
150mm
150mm
50mm
Non-combustible
board
* All combustible materials must be removed from behind the
appliance or a minimum distance of 100mm is required where the
combustible material is protected by non combustible board.
Non-combustible
board
Metal Stud
(Decorative Front
Installation only)
Metal Stud
(Decorative Front
Installation only)
6.2 DO NOT PACK THE VOID AROUND OR ABOVE THE
APPLIANCE WITH INSULATION MATERIALS SUCH AS
MINERAL WOOL.
6.3 THE VOID BUILT FOR THE CASSETTE MUST BE
VENTILATED TO PREVENT A BUILD-UP OF HEAT. IT IS
NECESSARY TO FIT VENTS AT BOTH LOW AND HIGH
LEVELS OF MINIMUM 200CM
2
EACH. THESE VENTS
MUST TAKE COLD AIR FROM THE ROOM AND RETURN
WARM AIR BACK INTO THE ROOM.
6.4 AN ACCESS HATCH MUST BE LEFT IN THE SIDE OF
THE CHIMNEY BREAST FOR FUTURE SERVICING AND
INSPECTION OF THE FLUE AND APPLIANCE.
This installation is Top Exit only. Use only a rigid twin
wall flue pipe.
6.5 There are 2 methods of installation into a studwork chimney:
6a. Edge finish Installation.
6b. Installation with a decorative front.
Carefully read the relevant section for the installation
method required.