4. Removing the Burner Assembly
4.1 Remove the 4 screws from the corners of the burner unit,
see Diagram 9.
9
Screws
Screws
4.2 Remove the rear bracket, see Diagram 10.
10
Bracket
4.3 Carefully remove the engine:
To do this slide the burner tray backwards, tilt the rear of the
tray upwards and twist to remove.
Place carefully to one side.
4.4 The gas supply enters through the silicone panel located on
the left-hand side on the rear of the outer box; this will need
to be slit with a sharp knife prior to passing the supply pipe
through, see Diagram 11.
11
4.5 Remove the Compression Elbow from the appliance.
5. Masonry Chimney Installation
5.1 There are 2 methods of installation into a masonry chimney:
5a. Edge finish Installation.
5b. Installation with a decorative front.
Carefully read the relevant section for the installation
method required.
5a. Edge Finish Installation
5a.1 This method is designed so that non-combustible board can
be taken right up to the edge of the flange of the appliance.
5a.2 Fix the self adhesive foam seal around the back of the fixing
flange of the appliance.
5a.3 Prepare the flue connection using the chosen method
described in Section 2.
5a.4 Connect the flue and install the appliance into the aperture.
At the same time ensure that the gas pipe passes through
the silicon panel at the back of the appliance.
5a.5 Secure the appliance through the 6 fixing holes using the
screws provided, see Diagram 12.
12
5a.6 Attach the Compression Elbow to the inlet pipe and secure
to the bracket on the inside of the firebox, see Section 7.
5a.7 Build the chimney breast up to coincide with the edge,
allowing for the front to be skimmed level.
5a.8 Fit non-combustible board to the chimney breast around the
appliance, using the distance to combustibles detailed in
Diagram 13.
13
Min 400mm
Bottom of Appliance
Min 150mm
Min 150mm