Riva2 600 600HL Conventional Flue Installation Instructions
17
Installation Instructions
The flue must be in good condition and clear products of
combustion, see Installation Instructions, Commissioning.
2.9 If a flexible liner is to be used check the seal on the inner lip
of the spigot plate is intact. Replace if necessary.
3
Options 3 and 4 (Studwork with Edge finish or decorative
front) must be fitted using the top exit only with rigid twin
wall flue pipe.
3. Removing the Glass Frame
3.1 Remove the glass frame by removing the 2 side trims, see
Diagram 4. These are held on by magnets.
4
3.2 Lift out the bottom slotted trim, see Diagram 5.
Note the orientation of the metal shield for reassembly.
5
3.3 Disconnect the battery lead from the battery pack attached to
the lower slotted trim, see Diagram 6.
6
4.6 Remove the screws at the base of the glass frame,
see Diagram 7 A.
7
A A
B
A
Riva2 600 only
4.7 Pull up the handle at the front, see Diagram 7 B.
3.6 Whilst supporting the top, lift the glass frame using the
handle, up and over the lower edge, see Diagram 8.
8