Riva2 600 600HL Conventional Flue Installation Instructions
12
Installation Instructions
Model
Gas
CAT.
Gas Type
Working
Pressure
Aeration Injector
Gas Rate
m
3
/h
Input kW
(Gross)
Country
High Low
Riva2 600 I
2H
Natural (G20) 20mb 2 x 4.5mm 390 0.657 6.9 4.6 GB, IE
Riva2 600 I
3P
Propane (G31) 37mb 2 x 12mm 128 0.244 6.5 3.8 GB, IE
Riva2 600HL I
2H
Natural (G20) 20mb 2 x 6mm 78A 0.733 7.7* 4.6 GB, IE
Riva2 600HL I
3P
Propane (G31) 37mb 2 x 11mm 128 0.188 6.6 3.8 GB, IE
600: Efciency Class 2 - 80% / NO
x
Class 4
600HL: Efciency Class 2 - 76% / NO
x
Class 4
Flue Size - TOP EXIT Ø 127mm
Flue Size - REAR EXIT 178mm ø minimum
Gas Inlet Connection Size Ø 8mm
Minimum Flue Specication = T250/N2/0/D/1
Maximum Flue Temp = 220°C
Technical Specification
Covering the following models:
The net efficiency of this appliance has been measured as specified in EN613:2001 and the result after conversion to gross
using the appropriate factor from Table E4 of SAP 2012 is 72.1% (Riva2 600) / 69.6% (Riva2 600HL). The test data has been
certified by Kiwa Nederland BV.
The gross efficiency value may be used in the UK Government's Standard Assessment Procedure (SAP) for energy rating
of dwellings.
PACKING CHECKLIST
Qty Description Fixing kit containing
1 x Cassette and burner
assembly
1 x Back panel
1 x LH side panel
1 x RH side panel
1 x Log set (6 logs)
1 x Blanking Plate
1 x Instruction manual
6 x Woodscrews
6 x Wall plugs
1 x Self adhesive foam strip
1 x Handset
4 x AA cell batteries
1 x 9v cell battery
2 x Side lining brackets
2 x Rear lining brackets
This appliance has been certified for use in countries other than
those stated. To install this appliance in these countries, it is
essential to obtain the translated instructions and in some cases
the appliance will require modification. Contact Gazco for further
information.
* Riva2 600HL NG: The net input of the product is 6.9kW and does not normally require any addition purpose provided
ventilation or modification to the building in order to provide extra air circulation as a result of installing this product.
Riva2 600 Riva2 600HL
Nat Gas 134-297 134-316
LPG 134-618 134-658