Changing the Default Timer Mode
It is possible to change the default time period for the Timer mode.
The default time period for Timer mode is factory set to
1 hour.
To change the default time:
Holding the remote to keep the green light on and the
handset unlocked:
2b.40 Press and hold the SET button until a beep is heard to
indicate the command has been received.
2b.41 Release the SET button. PROG will be displayed at the top
left of the display.
2b.42 Repeatedly press the MODE button until the Zzz symbol
flashes at the top of the display.
2b.43 Press and release the SET button.
2b.44 Press the + or - buttons to alter the default time period.
The timer can be set between 1 minute and 24 hours.
2b.45 After adjusting the time press SET again to confirm.
Note: This does not activate the Timer mode, see
Installation Section, Manual Operation or Thermostatic
Mode.
3. Slide Control
This appliance is operated using the slide control on the top
right hand side of the decorative front.
When the appliance is OFF the slide control will be at the
highest point, see Diagram 9.
9
OFF
Ignition Point
Low Setting
High Setting
Lighting the Pilot
3.1 Push the slide control down as far as possible to its lowest
point, see Diagram 8, this is the ignition point.
Keep the slide control pressed down for 5 seconds to
ensure the pilot is lit. Then release.
The appliance should light on its lowest setting.
3.2 When released the slide control automatically raises to a
natural stop point, see Diagram 9.
Repeat the above steps if the appliance does not light.
3.3 If, after repeating the above steps the pilot does not light,
contact your Retailer or Installer.
Adjusting the Flame height
3.4 Increase the flame height and temperature by carefully
moving the slide control up until the next stop point is felt,
see Diagram 9. This denotes the highest setting.
3.5 Carefully move the slide control down to the lower stop point
to return to the lowest setting.
IMPORTANT: YELLOW FLAMES TYPICALLY
APPEAR WHEN THE APPLIANCE HAS REACHED
NORMAL OPERATING TEMPERATURE. THIS CAN
TAKE UP TO 30 MINUTES.
WARNING: IF THE APPLIANCE FAILS TO LIGHT OR
BECOMES EXTINGUISHED IN USE, WAIT 3
MINUTES BEFORE ATTEMPTING TO RELIGHT.
Switching OFF the Appliance
3.6 To turn the appliance off lift the slide control to its highest
stop point, see Diagram 9. The pilot goes out.
4. Replacing the Appliance Batteries
Replace batteries at least every 12 months during the annual
service of the fire.
It is essential to use high quality batteries (Duracell
or equivalent) when replacing batteries.
4a. Remote Control
The icon at the bottom shows the battery condition of both the
batteries in the handset and in the Control Box alternately, see
Diagram 10.
10
Battery status
RC = Remote Control Handset and FC = Fire Control