Logic HE Range Conventional Flue Log Effect Installation User Instructions

11
4b. Slide Control
4b.1 The battery box is located at the bottom left of the appliance
behind the ash cover, see Diagram 15.
15
9V Battery
Ignition
Unit
4b.2 Remove the old battery and replace with a new high quality
(Duracell or similar) 9V battery.
It is essential to use high quality batteries (Duracell
or equivalent) when replacing batteries.
5. Cleaning the Appliance
5.1 Make sure the appliance and surrounds are cool before
trying to clean.
5.2 Refer to the separate decorative front instructions to remove
the front from the appliance.
5.3 Remove the glass frame by removing the 4 screws in the
retaining bracket, see Diagram 16.
Detail A
A
16
5.4 Tilt the top of the glass frame forward and disengage
the lower location tabs from the slots in the firebox, see
Diagram 16, Detail A. Place carefully to one side.
5.5 To clean the glass surface, Gazco recommends you use hot
soapy water.
5.6 The glass frame must be refitted to the appliance following
cleaning or servicing.
Ensure that the rope seal on the box is intact, then locate
the glass frame location tabs into the slots on the firebox,
see Diagram 16, Detail A.
5.7 Secure the glass frame using 4 screws in the retaining
bracket, see Diagram 16.
Replace ALL of the securing screws ensuring that a screw is
present in all fixing slots.
NEVER OPERATE THE APPLIANCE WHEN THE GLASS
FRAME IS REMOVED OR BROKEN.
Refer to the separate decorative front instructions to replace
the front on the appliance.
UNDER NO CIRCUMSTANCES SHOULD THE
APPLIANCE BE USED IF ANY OF THE GLASS
FRAME RETAINING SCREWS ARE LOOSE OR
MISSING.
6. Arrangement of the Fuel Bed
Advice on handling and disposal
of fire ceramics
The fuel effect and side panels of this
appliance are made from Refractory Ceramic
Fibre (RCF), a material which is commonly
used for this application.
Protective clothing is not required when
handling these articles, but we recommend you
follow normal hygiene rules of not smoking,
eating or drinking in the work area and always
wash your hands before eating or drinking.
To ensure that the release of RCF fibres
are kept to a minimum, during installation
and servicing a HEPA filtered vacuum
is recommended to remove any dust
accumulated in and around the appliance
before and after working on it. When servicing
the appliance it is recommended that the
replaced items are not broken up, but are
sealed within heavy duty polythene bags and
labelled as RCF waste.
RCF waste is classed as stable, non-reactive
hazardous waste and may be disposed of at a
licensed landfill site.
Excessive exposure to these materials may
cause temporary irritation to eyes, skin and
respiratory tract; wash hands thoroughly after
handling the material.
7. Log Layout
LOGS MUST BE POSITIONED ACCORDING TO THE
FOLLOWING INSTRUCTIONS TO GIVE THE CORRECT
FLAME EFFECT.
7.1 Ensure the burner tray is clean and free from any debris, see
Diagram 17.
17