Logic HE Balanced Flue Log Installation User Instructions
9
User Instructions
3. Slide Control
This appliance is operated using the slide control on the top
right hand side of the decorative front.
When the appliance is OFF the slide control will be at the
highest point, see Diagram 9.
9
OFF
Ignition Point
Low Setting
High Setting
Lighting the Pilot
3.1 Push the slide control down as far as possible to its lowest
point, see Diagram 8, this is the ignition point.
Keep the slide control pressed down for 5 seconds to
ensure the pilot is lit. Then release.
The appliance should light on its lowest setting.
3.2 When released the slide control automatically raises to a
natural stop point, see Diagram 9.
Repeat the above steps if the appliance does not light.
3.3 If, after repeating the above steps the pilot does not light,
contact your Retailer or Installer.
Adjusting the Flame height
3.4 Increase the flame height and temperature by carefully
moving the slide control up until the next stop point is felt,
see Diagram 9. This denotes the highest setting.
3.5 Carefully move the slide control down to the lower stop point
to return to the lowest setting.
IMPORTANT: YELLOW FLAMES TYPICALLY
APPEAR WHEN THE APPLIANCE HAS REACHED
NORMAL OPERATING TEMPERATURE. THIS CAN
TAKE UP TO 30 MINUTES.
WARNING: IF THE APPLIANCE FAILS TO LIGHT OR
BECOMES EXTINGUISHED IN USE, WAIT 3
MINUTES BEFORE ATTEMPTING TO RELIGHT.
Switching OFF the Appliance
3.6 To turn the appliance off lift the slide control to its highest
stop point, see Diagram 9. The pilot goes out.
4. Replacing the Appliance Batteries
Replace batteries at least every 12 months during the annual
service of the fire.
It is essential to use high quality batteries (Duracell
or equivalent) when replacing batteries.
4a. Remote Control
The icon at the bottom shows the battery condition of both the
batteries in the handset and in the Control Box alternately, see
Diagram 10.
10
Battery status
RC = Remote Control Handset and FC = Fire Control
(Control Box).
Note: Change the batteries in the handset before
they are flat, to avoid having to reprogram the time
of day in again. N.B. Pairing is not lost, even if the
batteries are removed or flat.
The appliance Control Box requires 3 AA size alkaline batteries.
The handset requires 2 AA size alkaline batteries.
4a.1 The appliance battery is located in the Control Box at the
bottom of the appliance behind the ash cover.
4a.2 Slide the white Power Switch on the Control Box to the
OFF position before attempting to change the batteries.
11
Power Switch