Model
Logic HE BF
Remote Control
NG Log
Logic HE BF
Remote Control
LPG Log
Logic HE BF
Slide Control
NG Log
Logic HE BF
Slide Control
LPG Log
Fuel
Space Heating Emissions (NOx) - mg / kWh
input
(GCV) 130 130 130 130
Heat
Output
Nominal Heat Output - P
nom
3.3kW 3.2kW 3.3kW 3.3kW
Minimum Heat Output (indicative) - P
min
1.8kW 1.8kW 1.9kW 1.9kW
Auxiliary
Electricity
Consumption
At Nominal Heat Output - el
max
N/A N/A N/A N/A
At Minimum Heat Output - el
min
N/A N/A N/A N/A
In Standby Mode - el
sb
N/A N/A N/A N/A
Useful
Efciency
(NCV)
Useful Efciency at nominal heat output - η
th,nom
86.0% 86.0% 86.0% 86.0%
Useful Efciency at minimum heat output (indicative) - η
th,min
79.3% 81.5% 79.3% 81.5%
Permanent
Pilot Flame
Power
requirement
Permanent Pilot Flame Power requirement (if applicable) - P
pilot
N/A N/A N/A N/A
Type of heat output/room temperature control
Two or more manual stages, no room temperature control No No Yes Yes
Electronic thermostat + day timer Yes Yes No No
Other control options (multiple selections possible)
Room temperature control, with presence detection No No No No
Room temperature control, with open window detection No No No No
With distance control option No No No No
With adaptive start control No No No No
With working time limitation No No No No
With black bulb sensor No No No No
Energy Efciency Index 82.0% 82.0% 77.0% 77.0%
Energy Efciency Class B B C C