Logic HE Balanced Flue Log Installation User Instructions

14
Installation Instructions
Technical Specification
Covering the following models:
Model
Gas
Cat.
Gas Type
Working
Pressure
Aeration Injector
Gas Rate
m
3
/hr
Input kW
(Gross)
Country
High Low
Logic HE BF
Log
Remote
I
2H
Natural Gas G20 20mbar 2 x 4mm 161 0.400 4.2 2.5 GB, IE
I
3P
Propane G31 37mbar 2 x 12mm 104 0.154 4.1 2.5 GB, IE
Logic HE BF
Log
Slide
I
2H
Natural Gas G20 20mbar 2 x 4mm 161 0.419 4.3 2.6 GB, IE
I
3P
Propane G31 37mbar 2 x 12mm 104 0.158 4.2 2.6 GB, IE
Efciency 86% Net (Class 1)
NOx Class 4
Flue Outlet Size Ø 100mm
Flue Inlet Size Ø 152mm
Gas Inlet Connection Size Ø 8mm
The net efficiency of this appliance has been measured as specified in EN613:2001 and the result after conversion to
gross using the appropriate factor from Table E4 of SAP 20012 is 79.9%. The test data has been certified by Kiwa
Nederland BV. The gross efficiency value may be used in the UK Government's Standard Assessment Procedure (SAP) for
energy rating of dwellings.
PACKING CHECKLIST
Qty Description Fixing Kit containing:
Log Version
1 x Log Set
1 x Lava Rock
1 x Instruction Manual
1 x Embaglow
1 x 1.7m Silicone Seal
4 x Wall Plugs
4 x Wood Screws
1 x 9V Battery (Slide Only)
5 x AA Battery (Remote Only)
Gas Type
LoGic He Bf
Remote Control Slide Control
Nat Gas 101-014 101-281
LpG 101-666 101-516