Logic HE Balanced Flue Combined Controls Installation User Instructions
26
Lighting the Pilot
10.3 Push the valve knob in and rotate anti-clockwise slowly
until a click is heard.
The pilot should now be lit.
10.4 Hold in for a further 10 seconds.
When released the pilot should remain lit.
If the pilot does not remain lit, repeat until the operation is
successful.
Locating the Pilot
Coal Effect
The pilot is located on the front right hand side of the
appliance. To view the pilot look down through the GAZCO
logo between the glass and the front coal, Diagram 30.
Front Coal
Gap in logo
30
White Stone Effect
The pilot is located on the rear right hand side of the
appliance and is clearly visible when lit, see Diagram 31.
31
Installation Instructions
Adjusting the Flame height
10.5 From the pilot position push the valve knob in slightly and
rotate anti-clockwise until the first stop point is felt.
This denotes the lowest setting.
10.6 Push the valve knob in slightly and rotate further in an anti-
clockwise direction.
The final stop point is the highest setting.
Pilot
position
Low Setting
High Setting
Off position
32
IMPORTANT: YELLOW FLAMES TYPICALLY
APPEAR WHEN THE APPLIANCE HAS REACHED
NORMAL OPERATING TEMPERATURE. THIS CAN
TAKE UP TO 30 MINUTES.
WARNING: IF THE APPLIANCE FAILS TO LIGHT OR
BECOMES EXTINGUISHED IN USE, WAIT 3
MINUTES BEFORE ATTEMPTING TO RELIGHT.
Switching OFF the Appliance
10.7 To switch the appliance off turn the control knob clockwise
until it is returned to the off position, see Diagram 33.
33
Rotate
clockwise
Rotate clockwise
The knob should be upright.