PACKING CHECKLIST
Qty. Description Fixing kit containing
1 x Cassette and burner
assembly
1 x Set of lining panels
1 x Log set (5 logs)
2 x Large Embers
1 x Pilot Ember
2 x Small Embers
1 x Shale Effect pack
1 x Amber Effect pack
1 x Instruction manual
1 x Handset
2 x AAA cell batteries
1 x Wall Mounting Bracket
8 x M8 Anchor bolts
1 x 75mm Restrictor
This appliance has been certied for use in countries other than
those stated. To install this appliance in these countries, it is
essential to obtain the translated instructions and in some cases
the appliance will require modication. Contact Gazco for further
information.
TECHNICAL SPECIFICATION
RESTRICTOR REQUIREMENT - VERTICAL & HORIZONTAL FLUE SPECIFICATION
Reex 75T
Vertical ue height from top of appliance Horizontal length Restrictor size
500mm - 999mm Up to 500mm N/A
1000mm - 1499mm Up to 1000mm N/A
1500mm - 3000mm Up to 5000mm N/A
TOP EXIT - VERTICAL ONLY INCLUDING OFFSET
Vertical ue height from top
of appliance
Restrictor size
1500mm - 2999mm 75mm
3000mm - 5999mm 70mm
6000mm - 10000mm 60mm
Restrictor Table
Mains Power In
Earth
LED
Pilot Burner
Control Value
Thermocouple
Solenoid Valve
Solenoid
Supply Lead
Control Valve Supply
Control Box
Electric Module
Light
Supply
Ignition Lead
TC Lead
SW Lead
Wi-Fi Module
(Optional)
WIRING DIAGRAM