Reflex 75T Multi Sided Balanced Flue Installation Manual
7
INSTALLATION INSTRUCTIONS
Model
Gas
CAT.
Gas Type
Working
Pressure
Gas Rate
m
3
/h
Input kW (Gross)
Country
High Low
Reex 75T I
2H
Nat Gas G20 18mbar 1.000 10.5 4.3
GB, IE
Reex 75T I
3+
Propane G31 37mbar 0.376 10.0 4.1
Efciency Class 1 - 92% / NO
x
Class 4
Flue Outlet Size Ø 100mm
Flue Inlet Size Ø 152mm
Gas Inlet Connection Size Ø 8mm
TECHNICAL SPECIFICATION
Covering the following models:
The net efciency of this appliance has been measured as specied in EN613:2001 and the result after conversion to gross
using the appropriate factor from Table E4 of SAP 2012 is 81.9%. The test data has been certied by Kiwa Nederland BV.
The gross efciency value may be used in the UK Government's Standard Assessment Procedure (SAP) for energy rating of
dwellings.
Power Supply: A 230V +/- 10% - 50Hz
Maximum power consumption: 9 Watts
Operating Temperature: 0°C - 40°C
THIS APPLIANCE MUST BE EARTHED
A 2 metre lead with plug containing a 3 amp fuse is
supplied. Only use a 3 amp fuse with this appliance.
Nat Gas LPG
Reex 75T 3-Sided 191-004 191-543
Reex 75T 2-Sided Left Facing Glass 191-010 191-414
Reex 75T 2-Sided Right Facing Glass 191-027 191-438