Reflex 75T Multi Sided Balanced Flue Installation Manual

46
Remove the 8 way cable from the Control Box.
8 Way
Cable
Interrupter Leads
Ignition lead
LED Lead
Module
Lead
Solenoid
Lead
Thermocouple
Pilot Pipe
Control
Box
Module
Solenoid
Replace in reverse order.
After replacing the Control Box ensure that all cable ties and
connections are refitted.
After replacing the Control Box you will need to reprogram the
handset.
— Press and hold the reset button on the control box until
you hear two signals. After the second longer signal:
— Release the reset button and within 20 seconds:
— Press the DOWN button on the handset until you hear
two additional short signals confirming the new code is
set. If there is a single long signal the code learning
sequence has failed or the wiring is incorrect.
Note: When pressing the DOWN button on the handset if two
beeps are not heard:
Release the DOWN button and CONN will be displayed
on the handset screen. An 8 second count will start on the
handset screen followed by two short beeps conrming
the new code is set. If there is a single long signal the
code learning sequence has failed or the wiring is
incorrect.
FUEL BED INJECTORS
This appliance has 6 Fuel Bed Injectors.
NOTE: The injectors are not identical, see Page 8.
TO ENSURE CORRECT ASSEMBLY REPLACE EACH
INJECTOR INDIVIDUALLY.
Remove the Magnetic Trim, Front Glass, Log Burners and Mesh
Tray.
Remove the 2 nuts and lock washers from each Burner Bracket.
Remove the Gasket.
Gasket
Undo the Injectors individually.
Replace with the correct size Injector.
See table on Page 12.
NOTE: DO NOT OVERTIGHTEN.
Use thread sealant Loctite 572 when replacing Injectors.
Repeat for the remaining Injectors.
Check for leaks.
SERVICING INSTRUCTIONS