Reflex 75T Multi Sided Balanced Flue Installation Manual
44
REPLACING THE MODULE
Remove the magnetic trims, and the lower Glass Support Bracket.
Remove the module cover and disconnect the LED plug and Mains
Lead from the Module.
Mains Lead
Module
Lead
LED Plug
Disconnect the Module Lead.
The Module can now be removed.
Replace in reverse order.
PILOT UNIT ASSEMBLY
Turn off the gas supply at the isolating device.
Remove the Log Burners and Main Control Assembly.
The pilot bracket can be accessed from the underside of the Main
Control Assembly.
IMPORTANT: UNDER THE TERMS OF THE
EXTENDED WARRANTY IT WILL BE COMPULSORY
TO CHANGE THE COMPLETE PILOT UNIT ON THIS
APPLIANCE IN YEARS 2 AND 4.
Undo pilot pipe from the control valve, see Arrow A.
Remove the thermocouple from the interrupter block, See Arrow B.
A
B
C
Remove the ignition lead from the electrode, see Arrow C.
Undo the 2 retaining screws from pilot unit bracket.
The pilot bracket can now be withdrawn from its cradle.
The pilot assembly consists of three components, which can be
individually changed, these are:
Electrode.
Pilot Injector.
Thermocouple.
Electrode
Thermocouple
Pilot Injector
Screws
Ignition Lead
Pilot Pipe
ELECTRODE
Pull the ignition lead off the electrode and undo the retaining nut,
see arrow A.
A
B
C
Replace with a new electrode. Do not over-tighten the nut; this
could break the component.
Replace the ignition lead.
PILOT INJECTOR
With the pilot assembly removed, undo the nut to drop the injector
out from the burner, see Arrow B.
THERMOCOUPLE
Undo the brass nut to remove the thermocouple from the pilot
burner unit, see Arrow C.
SERVICING INSTRUCTIONS