Reflex 75T Multi Sided Balanced Flue Installation Manual

42
Screws
4
Turn the gas supply off at the isolation device.
HAVE YOU ISOLATED THE GAS SUPPLY?
Disconnect the isolating device from the appliance inlet pipe (A) to
isolate the gas supply.
Elbow
A
5
Remove the remaining screws securing the Main Control Assembly
to the rebox.
6
Disconnect the LED lead and the Receiver lead from the power
module. If tted, disconnect the Wi-Fi lead from the Wi-Fi module.
Lift the rear and slide to the right.
The Main Control Assembly can now be removed.
4.15 Replace in reverse order.
AFTER SERVICING ENSURE THAT ALL
CONNECTIONS ARE REPLACED BEFORE
REPLACING THE MESH TRAY.
SERVICING INSTRUCTIONS
REPLACING THE LED CIRCUIT
There are 3 LED boards, which can be replaced individually.
Driver
Front LED 1
Front LED 2
Rear LED bar
THE LED'S ARE FRAGILE. HANDLE WITH CARE.
ONLY HOLD THE LED BOARDS BY THE EDGES TO
AVOID CONTACT WITH THE TOP OF THE LED'S.
AVOID CATCHING ANY DELICATE WIRES WHEN
REPLACING THE SCREWS.
Remove the Main Burners and the Mesh Tray.
Front LED boards
There are two LED boards located on a shelf below the top of the
Control Assembly.
1
Lift the brackets away from the appliance.
Remove the screw from the module cover and carefully lift to
remove.