Reflex 75T Multi Sided Balanced Flue Installation Manual

39
SERVICING INSTRUCTIONS
GENERAL
All main components can be replaced without removing the
appliance from its installation.
DISCONNECT MAINS ELECTRICAL SUPPLY AT THE
ACCESSIBLE PLUG OR DEDICATED SWITCH BEFORE
SERVICING THE APPLIANCE.
IT IS ESSENTIAL THAT THE GAS SUPPLY TO THE APPLIANCE
IS TURNED OFF AT THE ISOLATION DEVICE BEFORE
PROCEEDING FURTHER.
It will be necessary to remove the burners and the fuel bed before
any of the main components can be serviced.
The Power Module and the Wi-Fi Receiver can be serviced by
removing the decorative trim and lower glass retaining bracket.
DURING SERVICING OF THIS APPLIANCE IT MAY
BE NECESSARY TO CUT CABLE TIES IN ORDER TO
ACCESS AND REMOVE SOME OF THE PARTS.
THESE MUST BE REPLACED WHEN
REASSEMBLING THE APPLIANCE.
AFTER SERVICING ENSURE THAT ALL
CONNECTIONS ARE REPLACED BEFORE
REPLACING THE MESH TRAY.
REMOVING THE GLASS
2 SIDED MODELS
The following instructions assume a left facing glass model. If tting
a right facing glass model the instructions are still correct, however,
the images may not wholly reect the installation in question.
If tted, remove the decorative trims.
1. Loosen.
2. Slide bracket.
1
2
Repeat for the 2 upper Brackets and 2 lower Brackets.
62
Upper Side Brackets
Lower Side Brackets
With the brackets disengaged, carefully slide the side glass panel
forward, lift, and swing the bottom out to remove.
Place the glass carefully to one side.
1.
2.
3.
Ensure that no fuel effect has fallen into the side glass
channels.
ALL MODELS
1