Reflex 75T Multi Sided Balanced Flue Installation Manual
27
INSTALLATION INSTRUCTIONS
GAS SOUNDNESS PRESSURE CHECK
Connect a suitable pressure gauge to the test point located on the
inlet tting. Turn the gas supply on.
Elbow
Remove the xing screws and loosely place the appropriate
burners onto the injectors.
Light the appliance and check all gas joints for possible leaks. Turn
the appliance to maximum and check that the supply pressure is as
stated on the databadge. Turn the appliance off. Replace the test
point screw and check the test point for leaks.
Remove the burners. Take care as the burners will be hot.
Replace the access panel, securing with the 4 screws.
ASSEMBLING THE FUEL BED
1
2
Tighten Rear Screws
Replace Front Screws
3
NOTE: Ensure the 2 brackets at the rear are pushed
as far back as possible before tightening.
Position the left hand Log Burner so that the right hand side is
angled up towards the centre of the rebox and the screw hole is
positioned at the front.
Screws
4
Position the right hand Log Burner so that the left hand side is
angled up towards the centre of the rebox and the screw hole is
positioned at the front.
NOTE: THIS BURNER IS SHORTER THAN THE OTHER TWO.
Position the centre Log Burner, so that the screw hole is positioned
at the front.
Only Secure the burners with the screws provided.