INSTALLATION INSTRUCTIONS
ENCLOSURE CONSTRUCTION
2 SIDED INSTALLATION
VENTILATION
Note: If the lower section of the enclosure is sealed
(to the oor or capped if designed as a oating
shelf) it will be necessary to provide a vent with a
cut size of 300cm
2
on each side.
If the upper section is sealed (to the ceiling or
capped if designed as a oating shelf) it will be
necessary to provide a vent with a cut size of
300cm
2
on each side.
Gazco recommend building the enclosure from the following
materials:
Metal Studwork
Non-combustible board:
Masterboard or Promafour - NOT PINK BOARD
Heart Resistant Plaster: Purimacho (any spider cracks that develop
after installation will need to be rubbed down and relled with Puri-
macho heat resistant ller to stablise).
Ensure all distances to combustible materials are maintained
Example enclosure
6. Upper Front Panel
5. Lower Front Panel
3. Open
Side Panel
7. Front
Side Panel
8. Short
Side
Panel
4. Lower Base Panel
2. Upper Inner Panel
1. Closed Side Panel
(If not installing