Reflex 75T Multi Sided Balanced Flue Installation Manual

16
INSTALLATION INSTRUCTIONS
REMOVING THE MESH AND
ACCESS PANEL
Loosen Rear Screws
Remove Front Screws
1
Reex 75T
NOTE: The left and right hand rear screws secure the 2 lower liner
tabs.
Slide the Mesh Tray forward slightly to disengage from the rear
screws and carefully lift over the Log Burner Brackets, Pilot and
Cross Lighter.
Remove through the front of the appliance.
Screws
2
Reex 75T
The gas supply enters through the Silicone Panel located on the
left-hand side of the outer box base; this will need to be slit with a
sharp knife prior to passing the supply pipe through.
3
The Isolation Elbow needs to be attached to the gas pipe before
installation, see diagram for location.
Rear Wall
Centre Line
185mm
289mm
Silicone Panel
(Approx location)
Outer Box
4
The appliance stands off the wall by 55mm.
It will be necessary to build a studwork enclosure to house the
mounting bracket and separate enclosures for the upper and lower
faces of the appliance.
WARNING: This appliance weighs 108Kg.
The manufacturer has designed this appliance to
attach to a masonry wall and all xings supplied
reect this. If siting on a studwork wall, the xing
points must be through the timber stud and not
plasterboard. Use appropriate xings.
DO NOT attach solely to a plasterboard wall.
The xings supplied for the Wall Mounted Kit are
R-RBL Rawlbolts and should be tted in the method
described below.
2 3
1
Ensure a minimum substrate thickness of 100mm.
1. Drill a hole - Diameter: 14mm x Depth: 65mm.
Note: When xing into brickwork, mortar joints should
be avoided
Remove debris and thoroughly clean hole with brush
and pump
2. Remove pre-assembled bolt and washer. Insert shield
into hole and tap home with hammer until ush with
surface
3. Insert bolt with washer through xture into the shield
Tighten to 15Nm torque.