Reflex 75T Multi Sided Balanced Flue Installation Manual
12
INSTALLATION INSTRUCTIONS
TOP FLUE VERTICAL OFFSET
KIT (8530/8530AN)
Used with kit 8524. A minimum rise of 500mm (191/2) is required to
the rst bend.
OPTIONAL EXTRA FLUE LENGTHS
AND BENDS
All ue components are 150mm diameter (6")
NOMINAL
LENGTH
ACTUAL
LENGTH
STAINLESS
FINISH
ANTHRACITE
FINISH
200mm 140mm 8527 8527AN
500mm 440mm 8528 8528AN
1000mm 940mm 8529 8529AN
45° Bend N/A 8507 8507AN
90° Bend N/A 8508 8508AN
NOTE: The following areas need careful consideration.
a) Terminal positions
b) Flue supports
c) Weatherproong
d) Fire precautions
For all the above options, local and national codes of practice
must be adhered to.
IMPORTANT:
1M VERTICAL, TERMINAL AND STRAIGHT FLUE
LENGTHS MUST NOT BE CUT!
REMOVING THE MOUNTING BRACKET
This appliance weighs 108Kg. The manufacturer
has designed this appliance to attach to a masonry
wall and all xings supplied reect this. However
if desired it is possible to locate the Reex on a
non-combustible studwork wall providing it is
constructed to give adequate load baring support.
I
f intending to install the appliance on a studwork
wall it is essential that the battens are located
across the xing areas of the wall mounting
bracket.
23mm
300mm
846mm
27mm
155mm
227mm
71mm
430mm
430mm
825mm
135mm
784mm
691mm
228mm
228mm
390mm
323mm
200mm
FLUE OPTIONS