Reflex 75T Multi Sided Balanced Flue Installation Manual
10
INSTALLATION INSTRUCTIONS
FLUE OPTIONS
REAR FLUE
Terminal dimensions:
395 x 200 x 200 mm (H x W x D)
Guard supplied
Cut to length as required on site.
IMPORTANT: REAR FLUE INSTALLATION
When fitting the appliance with a rear flue terminal
it is essential to observe distances to combustible
material when flue passes through a combustible
wall. Ensure the terminal is suitable protected if
fitting to an external combustible structure. There is
a fixing kit available from Gazco (Part No 999-220).
DO NOT INSTALL DIRECTLY ONTO A
COMBUSTIBLE SURFACE.
Decide on the terminal position.
Measure the height from the finished hearth level/ base of the
appliance to the centre of the required hole.
NOTE - Carefully consider:
a) Terminal positions
b) Flue supports
c) Weatherproofing
d) Fire precautions
For all the above options, you must conform to local and national
codes of practice.
Use only Gazco supplied flue on this appliance.
A guard (supplied) must be fitted to any terminal less than 2
metres above any access such as level ground, a balcony or
above a flat roof.
REFLEX 75T TOP EXIT FLUE
TOP FLUE UP AND OUT KIT (8523)
Vertical from the top of the appliance then horizontally out.
The basic kit comprises:
1 x 500mm terminal length
1 x 90 degree elbow
1 x 500mm vertical length
1 x wall plate
1 x 60mm restrictor
1 x 75mm restrictor
4 x xing screw
Start of bend to centre line of horizontal ue 170mm. Centre line of
vertical ue to end of bend 220mm.
This kit provides the minimum materials. Extra lengths can be
added to the vertical and horizontal sections.
Refer to Restrictor Table on page 9 to identify when to use a
restrictor.