Reflex 75T Conventional Flue User Installation Manual

42
12.4 Undo the Injectors individually and remove the bre washer,
see Diagram 33.
33
12.5 Replace with the correct size Injector.
NOTE: DO NOT OVERTIGHTEN.
12.6 Repeat for the remaining Injectors.
12.7 Check for leaks.
13. Cross Lighting Injector
13.1 Remove the Log Burners and Main Control Assembly,
see Section 4.
13.2 Undo the nut from the Main Control Assembly,
see Diagram 34 A.
13.3 Undo the nut from the Cross Lighter, see Diagram 34 B.
34
B
C
A
13.4 Remove the lock nut from the Injector, see Diagram 34 C.
13.5 Replace with the correct size Injector.
13.6 Ensure the left-hand side of the Burner engages in the
bracket slot.
13.7 Check for leaks.
Servicing Instructions - Replacing Parts
14. Latching Solenoid
14.1 Remove the Main Control Assembly, see Section 4.
14.2 Hold the brass adapter (large nut) with a 17mm spanner
and release the tube nut (small nut) from the adapter,
see Diagram 35.
35
Brass Adapter
Tube Nut
Tube Nut
14.3 Repeat on both sides of the Solenoid.
14.4 Remove the Solenoid plug from the Control Box,
see Diagram 29.
14.5 Cut the cable tie. NOTE the orientation of the cables.
14.6 Replace in reverse order.
Ensure that the cable ties are replaced.
15. Changing Between Gas Types
In order to change between gas types, it will be necessary
to change the following components:
Pilot
Main Injectors x 6
Crosslighting Injector
Gas Valve
Main Burner x 3
Contact your Gazco retailer for further information.
A kit of parts is available for this. Always quote the Model
number and Serial number when ordering any spare parts.