Reflex 75T Conventional Flue User Installation Manual

39
Servicing Instructions - Replacing Parts
6. Module
6.1 Remove the Log Burners, Mesh Tray and Air Guide, see
Section 4.
6.2 Disconnect the LED plug and Mains Lead from the Module,
see Diagram 21.
21
Mains Lead
Module
Lead
Screw
LED Plug
6.3 Disconnect the Module Lead, see Diagram 21.
6.4 Remove the screw securing the Module to the base of the
appliance, see Diagram 21.
6.5 The Module can now be removed.
6.6 Replace in reverse order.
7. Pilot Unit Assembly
IMPORTANT: UNDER THE TERMS OF THE
EXTENDED WARRANTY IT WILL BE COMPULSORY
TO CHANGE THE COMPLETE PILOT UNIT ON THIS
APPLIANCE IN YEARS 2 AND 4.
7.1 The Pilot Assembly needs to be replaced as a complete
unit.
7.2 Remove the Gauze Pilot Shield for access.
7.3 Remove the Log Burners and Main Control Assembly,
see Section 4.
7.4 Undo the compression nut from the pilot pipe,
see Diagram 22.
22
Compression Nut
7.5 Remove the ignition lead from the electrode, see
Diagram 23.
7.6 Undo the 2 retaining screws from pilot unit bracket, see
Diagram 23.
23
Ignition lead
Electrode
Screws
7.7 Undo the thermocouple nut from the interrupter block at the
rear of the gas valve, see Diagram 24.
24
7.8 Remove the Vidaex from the Thermocouple and ret to the
new Pilot Assembly.
7.9 When replacing the Pilot ensure the Thermocouple follows
its original route.
7.10 Set the spark gap, see Diagram 25.
25
15mm
4mm