4.10 Remove the 2 screws to remove the Access Panel, see
Diagram 9.
9
Screws
4.11 Turn the gas supply off at the isolation device.
HAVE YOU ISOLATED THE GAS SUPPLY?
4.12 Disconnect the isolating device from the appliance inlet pipe
to isolate the gas supply, see Diagram 10.
10
Elbow
4.13 Remove the 2 screws from the Air Guide, see Diagram 11.
11
Front Screws
4.14 Lift and rotate the Air Guide upwards from the front edge to
remove.
Note the orientation for reassembly.
NOTE: To replace; rotate and slide the Air Guide into
position with the ends locating under the side brackets.
Ensure that the angled metal is sloping towards the front of
the appliance.
4.15 Disconnect the Mains Lead Plug from the Module, see
Diagram 12.
DO NOT REMOVE THE WIRES FROM THE PLUG.
12
Mains Lead
2 Wing Nuts
4.16 Undo the 2 wing nuts, see Diagram 12.
4.17 Lift and slide the Main Control Assembly slightly to the right
and remove through the front of the appliance.
Place carefully to one side.
4.18 Replace in reverse order.
AFTER SERVICING ENSURE THAT ALL
CONNECTIONS ARE REPLACED BEFORE
REPLACING THE MESH TRAY.
5. Replacing the LED Boards
There are 3 LED boards, which must be replaced as a unit.
THE LED'S ARE FRAGILE. HANDLE WITH CARE.
ONLY HOLD THE LED BOARDS BY THE EDGES
TO AVOID CONTACT WITH THE TOP OF THE
LED'S.
AVOID CATCHING ANY DELICATE WIRES WHEN
REPLACING THE SCREWS.
5.1 Remove the Log Burners and Main Control Assembly,
see Section 4.
5.2 From the rear of the Control Assembly remove the 2
screws securing the Resistor, see Diagram 13.
5.3 Disconnect the LED Mains Lead Plug from the Module.
5.4 Undo the screw to remove the right hand LED board, see
Diagram 13.
13
Screw
Module LED Plug
Resistor Screws
Wires