Reflex 75T Conventional Flue User Installation Manual

23
Installation Instructions
6b. Installation with a
Decorative Front
Mantels, Hearths & Slips
If tting this appliance with a decorative surround
it will be necessary to install the appliance with a
Hearth and Slip set.
The hearth must have a minimum depth of 225mm.
It is essential to ensure that a height of 123mm is
maintained from the nished oor to the bottom edge
of the viewing area.
Read these instructions in conjunction with the
manual supplied before installation.
6b.1 Build the studwork chimney breast and enclosures to the
required size to include the protected platform at the
desired height.
6b.2 Before tting the cladding, cut 2 200 x 100 mm² minimum
holes in the non-combustible side boards to allow air
circulation around the appliance vents,
see Diagrams 31 & 32.
31
25mm
min
12mm min
100
200
Front of
Studwork
6b.3 Line the aperture for the appliance with 12mm thick
non-combustible material as shown.
Non-combustible board used to protect the studwork can
line the aperture inside the 50mm clearance distance, see
Diagram 32.
32
Non-combustible
board
6b.4 Site the appliance and decide on ue requirements.
6b.5 Prepare the ue connection using the chosen method
described in Section 2 ensuring that distances to
combustible materials are maintained at all times.
Connect the ue and install the appliance into the aperture.
At the same time ensure that the gas pipe passes through
the silicon panel at the back of the appliance.
Provide electric services into the void on the right hand
side.
It is necessary to be able to disconnect the appliance
from the mains electrical supply after installation.
This may be achieved by an accessible plug or by
incorporating a switch into the fixed wiring in
accordance with the rules in force.
6b.6 Slide the metal plate, previously removed, over the gas pipe
and secure with a screw, see Diagram 33.
33
Screw
Metal Plate
Gas Supply
Do not secure the appliance at this time.
6b.7 Fit non-combustible board to the studwork around the
aperture. This should extend a minimum of 400mm above
the appliance and at least 200mm to the sides of the
appliance, see Diagram 34 and Diagram 35.
34
Min
400mm
Bottom of
Appliance
Min 200mm
Min 200mm
35
Non-combustible
Board
Appliance
Outer
Casing
Appliance
Edge
Combustible Stud
Heat resistant
Plaster
Appliance Flange