Reflex 75T Conventional Flue User Installation Manual

11
Installation Instructions
Model
Gas
CAT.
Gas Type
Working
Pressure
Gas Rate
m
3
/h
Input kW
(Gross)
Country
High Low
Reex 75T
I
2H
Natural Gas G20 20mbar 1.096 11.5 4.8
GB, IE
Reex 75T
I
3+
Propane G31 37mbar 0.433 11.5 4.5
Efciency Class 2 - 76 % / NO
x
Class 4
Flue Size - TOP EXIT Ø 127mm
Gas Inlet Connection Size Ø 8mm
Minimum Flue Specication = T250/N2/0/D/1
Maximum Flue Temp = 250°C
Technical Specification
Covering the following models:
The net efciency of this appliance has been measured as specied in EN613:2001 and the result after conversion to gross
using the appropriate factor from Table E4 of SAP 2012 is 69%. The test data has been certied by Kiwa Nederland BV.
The gross efciency value may be used in the UK Government's Standard Assessment Procedure (SAP) for energy rating of
dwellings.
Reflex 75T
Nat Gas
Reex 75T
LPG
Black Reeded 191-029 191-412
Vermiculite 191-033 191-424
Brick Effect 191-045 191-435
Ledgestone 191-051 191-448
Black Glass 191-062 191-459
Power Supply: A 230V +/- 10% - 50Hz
Maximum power consumption: 9 Watts
Operating Temperature: 0°C - 25°C
THIS APPLIANCE MUST BE EARTHED
A 2 metre lead with plug containing a 3 amp fuse is
supplied. Only use a 3 amp fuse with this appliance.
Aeration Table
NOTE: Aeration Holes are in each leg of the burners. These holes are different sizes at the Front and Back for each individual leg.
FRONT
Nat Gas 4.0 Ø
LPG 5.5 Ø (X2*)
REAR
Nat Gas 4.5 Ø
LPG 6.5 Ø (X2)*
FRONT
Nat Gas 4.0 Ø
LPG 6.5 Ø (X2)*
REAR
Nat Gas 3.5 Ø (X2)*
LPG 8.0 Ø (X2)*
FRONT
Nat Gas 4.0 Ø
LPG 6.0 Ø (X2)*
REAR
Nat Gas 4.0 Ø
LPG 6.0 Ø (X2)*
*(X2) indicates that a
hole is necessary in
each side of the leg.