Reflex 75T Balanced Flue User Installation Manual
56
CHANGING BETWEEN GAS TYPES
In order to change between gas types, it will be necessary to
change the following components:
Pilot
Main Injectors x 6
Crosslighting Injector
Gas Valve
Main Burner x 3
Contact your Gazco retailer for further information.
A kit of parts is available for this. Always quote the Model number
and Serial number when ordering any spare parts.
BAFFLE AND LINERS
BLACK REED, BRICK EFFECT AND LEDGESTONE
LINERS
These lining panel options are available for this
product and contains Refractory Ceramic Fibre
(RCF), a material which is commonly used for this
application.
RCF waste is classed as stable, non-reactive
hazardous waste and may be disposed of at a
licensed landll site.
If replacing these items do not break therm up.
Seal within heavy duty polythene bags and label as
RCF waste.
Protective clothing is not required when handling
these articles.
If the Liners are visibly broken Gazco recommend
using gloves and a face mask to remove the pieces
and remove any dust accumulated in and around the
appliance before and after working on it with a HEPA
ltered vacuum.
If any concerns remain contact Gazco Technical
Customer Services to obtain the manufacturers
COSHH Data Sheet.
The top bafe must be removed rst before accessing the lining set.
1
2
3
4
5a