Reflex 75T Balanced Flue User Installation Manual
52
REPLACING THE MODULE
Remove the module bracket and disconnect the LED plug and
Mains Lead from the Module.
Mains Lead
Module
Lead
Screw
LED Plug
Disconnect the Module Lead.
The Module can now be removed.
Replace in reverse order.
PILOT UNIT ASSEMBLY
Turn off the gas supply at the isolating device.
IMPORTANT: UNDER THE TERMS OF THE
EXTENDED WARRANTY IT WILL BE COMPULSORY
TO CHANGE THE COMPLETE PILOT UNIT ON THIS
APPLIANCE IN YEARS 2 AND 4.
Undo pilot pipe from the control valve (A).
Remove the thermocouple from the interrupter block (B).
Remove the ignition lead from the electrode (C).
Undo the 2 retaining screws from pilot unit bracket.
A
B
C
1
The pilot bracket can now be withdrawn from its cradle.
The pilot assembly consists of three components, which can
be individually changed, these are:
Electrode.
Pilot Injector.
Thermocouple.
Electrode
Thermocouple
Pilot Injector
Screws
Ignition Lead
Pilot Pipe
2
ELECTRODE
3
Replace with a new electrode.
Do not over-tighten the nut; this could break the component.
PILOT INJECTOR
4