Reconnect the Mains Lead Plug, the LED leads and the receiver
lead from the Module and the Wi-Fi box (if installed),
4
5
6
Connect power to the appliance.
GAS SOUNDNESS PRESSURE CHECK
Connect a pressure gauge to the test point
Elbow
1
Turn the gas supply on.
Loosely place the appropriate burners onto the injectors.
Light the appliance and check all gas joints for possible leaks. Turn
the appliance to maximum and check that the supply pressure is
as stated on the databadge.
Turn the appliance off.
Replace the test point screw and check the test point for leaks.
Remove the burners. Take care as the burners will be hot.