Reflex 75T Balanced Flue User Installation Manual

28
MASONRY INSTALLATION
DECORATIVE FRAME INSTALLATION
Mantels, Hearths & Slips
If tting this appliance with a decorative surround it
will be necessary to install the appliance with a Hearth
and Slip set.
The hearth must have a minimum depth of 225mm.
It is essential to ensure that a height of 123mm is
maintained from the nished oor to the bottom edge
of the viewing area.
Read these instructions in conjunction with the
manual supplied before installation.
1
Silicone
Strip
The appliance ange should sit ush to the brickwork and the edge
should sit proud of the wall.
2
Min
200mm
Min
150mm
Min: Bottom of the appliance
Min
200mm
Heat Resistant Plater
3
4
x6
The subframe for the decorative front can now be tted by following
the instructions supplied with the Front.
NOTE: THE SUBFRAME MUST SIT FLUSH TO THE
WALL LEVEL WITH THE APPLIANCE FLANGE.