Reflex 75T Balanced Flue User Installation Manual
27
MASONRY INSTALLATION
There are 2 methods of installation into a masonry chimney:
Edge nish Installation.
Installation with a decorative front.
Carefully read the relevant section for the installation method required.
This appliance is designed so that non-combustible board can be taken right up to the edge of the ange.
It is necessary to be able to disconnect the
appliance from the mains electrical supply after
installation.
This may be achieved by an accessible plug or
by incorporating a switch into the xed wiring in
accordance with the rules in force.
EDGE FINISH INSTALLATION
1
Silicone
Strip
2
3
x6
Fit non-combustible board to the chimney breast around the
appliance, using the distance to combustibles detailed
4
Min
200mm
Min
150mm
Min: Bottom of the
appliance
Min
200mm
Fit plasterboard to the remaining of the chimney breast front.
Apply a heat resistant plaster around the appliance using the
distance to combustibles detailed.
Apply a plaster nish to remaining chimney breast front.