Reflex 75T Balanced Flue User Installation Manual

21
SITE REQUIREMENTS
STUDWORK INSTALLATION
Combustible parts of the studwork must not be any closer than
the minimum dimensions shown in the diagrams. NOTE: These
dimensions must be maintained even if the combustible materials is
protected by non-combustible linings.
Build the studwork chimney breast to the desired size. Ensure that
the clearances to combustible materials is maintained.
A combustible shelf must be:
— Maximum 150mm in depth.
— Minimum 150mm high above the appliance.
A combustible side wall must be a minimum of 200mm from the
appliance.
PROTECT THE NEAREST STUDWORK WITH NON-
COMBUSTIBLE MATERIAL AND MAINTAIN THESE
DIMENSIONS AT ALL TIMES, SEE DIAGRAM 8.
MINIMUM
COMBUSTIBLE
MATERIAL
CLEARANCES
400mm
100mm
150mm
100mm
200mm
200mm
200mm
50mm
12mm
Non-combustible
board
Non-combustible
board
DISTANCE TO NON-COMBUSTIBLE OR COMBUSTIBLE
MATERIAL
TO CREATE ENOUGH CLEARANCE FOR THE TOP VENTS
IT IS IMPORTANT THAT NO PART OF THE STUDWORK
(COMBUSTIBLE OR NOT) IS BUILT ABOVE THE TOP OF THE
BOX.
NOTE: DO NOT ENCLOSE THE TOP OF THE VOID.
THE VOID MUST EXTEND TO THE CEILING.
It is recommended that a marble slip or similar material is used
when tting cassette replaces into a plastered surface, in order
to allow for heat dissipation. Also allow adequate time for newly
plastered areas to dry out. Rapid drying can create cracks. If in
doubt, seek the advice of a professional plasterer.
If tting this appliance with a decorative frame it
cannot be installed with the base of the appliance less
than 150mm from the oor level. The frame requires a
minimum clearance to allow air to circulate.
If this appliance is tted less than 225mm from the
oor, then it will require a hearth to protect the oor.
The hearth should have a minimum dimension of
12mm thick, projecting 225mm in front and 150mm
either side of the appliance.
The minimum opening dimensions are shown in Diagram 6.
NOTE: If using natural materials for the back panel of the
replace, it is recommended that it is constructed from three
or more sections to prevent cracking. Resin based materials
may not be suitable. This appliance is an effective heat
producer and attention must be paid to the construction and
nish of the replace.
This appliance is not suitable for installation onto a combustible
wall; all combustible materials must be removed from the area
shown.
1201
801
200
896
150
1046
Mantels, Hearths & Slips
If tting this appliance with a decorative surround it
will be necessary to install the appliance with a hearth
and Slip set.
The hearth must have a minimum depth of 225mm.
It is essential to ensure that a height of 123mm is
maintained from the nished oor to the bottom edge
of the viewing area.
Read these instructions in conjunction with the
manual supplied before installation.