Reflex 75T Balanced Flue User Installation Manual

18
REAR FLUE
Terminal dimensions:
395 x 200 x 200 mm (H x W x D)
Guard supplied
Cut to length as required on site.
IMPORTANT: REAR FLUE INSTALLATION
When fitting the appliance with a rear flue terminal
it is essential to observe distances to combustible
material when flue passes through a combustible
wall. Ensure the terminal is suitable protected if
fitting to an external combustible structure. There is
a fixing kit available from Gazco (Part No 999-220).
DO NOT INSTALL DIRECTLY ONTO A
COMBUSTIBLE SURFACE.
Decide on the terminal position.
Measure the height from the finished hearth level/ base of the
appliance to the centre of the required hole.
A masonry installation requires the addition of a suitable lintel to
support the opening. Refer to Installation Instructions, Technical
Information for details of the flue length.
NOTE - Carefully consider:
a) Terminal positions
b) Flue supports
c) Weatherproofing
d) Fire precautions
For all the above options, you must conform to local and national
codes of practice.
Use only Gazco supplied flue on this appliance.
A guard (supplied) must be fitted to any terminal less than 2
metres above any access such as level ground, a balcony or
above a flat roof.
TIMBER FRAMED BUILDINGS
It will be necessary to provide additional clearance when the flue
passes through a wall containing any combustible materials so as
to prevent a fire hazard.
The hole through which the flue will pass, must have a steel
sleeve which is positioned so that an air gap of at least 25mm is
maintained between the outer surface of the flue, and any part of
the sleeve.
For further guidance on the installation of gas appliances in timber
framed buildings, contact your local buildings control authority.
TOP EXIT FLUE
TOP FLUE UP AND OUT KIT
(8523)
Vertical from the top of the appliance then horizontally out, see
Diagram 3. The basic kit comprises:
1 x 500mm terminal length
1 x 90 degree elbow
1 x 500mm vertical length
1 x wall plate
1 x 60mm restrictor
1 x 75mm restrictor
4 x xing screw
Start of bend to centre line of horizontal ue 170mm. Centre line of
vertical ue to end of bend 220mm.
This kit provides the minimum materials. Extra lengths can be
added to the vertical and horizontal sections.
Refer to Installation Instructions, Technical Specication on page 17
to identify when to use a restrictor.