Reflex 75T Balanced Flue User Installation Manual

14
MODEL
GAS
CAT.
GAS TYPE
WORKING
PRESSURE
GAS RATE
M
3
/H
INPUT KW (GROSS)
COUNTRY
HIGH LOW
Reex 75T I
2H
Nat Gas G20 18mbar 0.953 10.0 4.1
GB, IE
Reex 75T I
3+
LPG G31 37mbar 0.369 9.8 4.3
Efciency Class 1 - 92 % / NO
x
Class 4
Flue Outlet Size Ø 100mm
Flue Inlet Size Ø 152mm Ø
Gas Inlet Connection Size Ø 8mm
TECHNICAL SPECIFICATION
Covering the following models:
The net efciency of this appliance has been measured as specied in EN613:2001 and the result after conversion to gross
using the appropriate factor from Table E4 of SAP 2012 is NG: 82.9%/LPG: 84.7%. The test data has been certied by Kiwa
Nederland BV.
The gross efciency value may be used in the UK Government's Standard Assessment Procedure (SAP) for energy rating of
dwellings.
Power Supply: A 230V +/- 10% - 50Hz
Maximum power consumption: 9 Watts
Operating Temperature: 0°C - 40°C
THIS APPLIANCE MUST BE EARTHED
A 2 metre lead with plug containing a 3 amp fuse is
supplied. Only use a 3 amp fuse with this appliance.
REFLEX 75T
NAT GAS
REFLEX 75T
LPG
Black Reeded 191-082 191-471
Vermiculite 191-094 191-487
Brick Effect 191-106 191-490
Ledgestone 191-111 191-512
Black Glass 191-127 191-528