Reflex 105 Multi-Sided Installation Instructions 1
55
ELECTRODE
Pull the ignition lead off the electrode and undo the retaining nut,
see arrow A.
A
B
C
3
Replace with a new electrode. Do not over-tighten the nut; this
could break the component.
Replace the ignition lead.
PILOT INJECTOR
With the pilot assembly removed, undo the nut to drop the injector
out from the burner, see Arrow B.
THERMOCOUPLE
Undo the brass nut to remove the thermocouple from the pilot
burner unit, see Arrow C.
IGNITION LEAD
Unplug the Ignition lead from the control box.
Ignition Lead
Carefully cut cable ties from the vidaflex and disconnect the lead
from the electrode.
IMPORTANT Ensure not to cut the cables.
NOTE: When replacing, ensure the ignition lead does not run
across the control box.
GAS VALVE
To change the gas valve:
Remove the Log Burners and Main Control Assembly.
Disconnect the Gas Inlet Pipe, Arrow A.
Disconnect the Gas Outlet Pipe, Arrow B.
Disconnect the Pilot Pipe, Arrow C.
Disconnect the Thermocouple, Thermocurrent Wires and the
Interrupter Block, Arrow D.
Remove the Eight Wire Loom, Arrow E.
There is an access hole abovce the cable plug oin the valve.
Insert a small screwdriver to release the locking tab.
C
D
A
B
E
Screw
Screw
Remove the 2 screws securing the Valve to the support bracket and
withdraw the Valve.
Replace in reverse order and check for leaks.
MAGNETIC SAFETY VALVE
Remove the Log Burners and Main Control Assembly.
Undo the Thermocouple from the Interrupter Block and remove the
2 Interrupter Leads.
Unscrew the Interrupter Block from the back of the Valve.
Undo the silver Magnetic Valve retaining nut on the back of the
Valve.
Gently tap out the Mag Valve.
Replace with a new unit.
Reassemble in reverse order ensuring that the interrupter leads are
connected correctly with the blue tag lead furthest away from the
gas valve body.
Check for leaks.