Reflex 105 Multi-Sided Installation Instructions 1
47
FAULT FINDING CHARTS
IGNITION FUNCTIONAL CHECK 1
PILOT WILL NOT LIGHT
Ensure there is no debris around the pilot assembly,
(e.g. soot, etc.) which could short the spark, clean the
area.
Operate the valve.
Is there a spark?
Consult User
Instructions and retry.
Check alignment of pilot
burner head, change the
ignition lead,
See section 7 Replacing Part
s
Check isolation tap and
gas meter, retry.
Correct and
retry.
Purge the gas pipes and
retry.
GO TO THE NEXT
CHART IGNITION
FUNCTIONAL CHECK 2
SYSTEM OK
There is a blockage in the system, check the inlet test point,
the mag seating, valve and pilot lter.
Is the gas turned on to
the appliance?
Is the gas pressure
correct?
Has the system got
any air in it?
Does the pilot light?
Is the control being
operated correctly?
Will the pilot light
with a match?
No
Yes
No
Yes
No
Yes
Yes
No
No
Yes
No
No
Yes
Yes