Reflex 105 Multi-Sided Installation Instructions 1
37
15
Minimum:
1070mm
Minimum:50mm
Minimum:
25mm Vertical
Overlay
Minimum
Height:
100mm
Minimum:
1000mm
Appliance
Enclosure Wall
Top View
50mm
Shadow Gap
GAS SOUNDNESS PRESSURE CHECK
This is a working pressure test and must be carried out with all
other gas appliances in the property in operation.
Connect a suitable pressure gauge to the test point located on the
inlet tting. Turn the gas supply on.
Test Point
Remove the xing screws and loosely place the appropriate
burners onto the injectors.
Light the appliance and check all gas joints for possible leaks. Turn
the appliance to maximum and check that the supply pressure is as
stated on the databadge. Turn the appliance off. Replace the test
point screw and check the test point for leaks.
Remove the burners. Take care as the burners will be hot.
1
2