Reflex 105 Multi-Sided Installation Instructions 1

26
FLUE ASSEMBLY
TAKE CARE WHEN MARKING OUT FOR THE FLUE AS IT IS
DIFFICULT TO MOVE AFTER INSTALLATION. IF A RESTRICTOR
IS REQUIRED FIT THIS BETWEEN THE SMALL OUTLET
SPIGOT AND THE AIR DUCT.
REFER TO TECHNICAL SPECIFICATIONS FOR RESTRICTOR
SIZE.
A 208mm diameter hole in the wall is required to install the ue.
This can be achieved by using either:
a) Core drill
b) Hammer and chisel
Drill small holes around the circumference when using
method b). Make good both ends of the hole.
Allow enough room either above or to the side of the appliance to
assemble the ue on top.
Assemble a horizontal ue in the following order:
— Vertical section
— 90° elbow
— Horizontal plus terminal
Only the horizontal terminal section can be reduced in size.
To nd the length:
Measure from the outside of the wall to the stop on the 90° elbow.
Add 10mm to the outlet end.
Measure from the edge of the slots closest to the wall.
Mark around the ue.
10mm
Bend the tab to 90°.
Assemble the plate onto the ue but do not secure to wall until the
ue is fully assembled.
The cardboard tment in the terminal is used to support the ue
whilst it is cut to length. ONCE CUT TO SIZE REMOVE THE
CARDBOARD REMNANT.