Reflex 105 Multi-Sided Installation Instructions 1
18
FLUE OPTIONS
All ue installations must be constructed in
accordance with the rules in force.
UK - Building Regulations: Approved Document J.
8" TOP FLUE UP AND OUT KIT
(999-333/999-333AN)
NOTE: This product is designed for and requires an
8" ue system. It is essential when ordering additional
parts to consult table 1 for the relevant part numbers.
Start of bend to centre line of horizontal ue 198mm. Centre line of
vertical ue to end of bend 248mm.
Vertical from the top of the appliance then horizontally out, see
Diagram. The basic kit comprises:
1 x Horizontal Flue Terminal
1 x 1000mm Length
1 x 90 Degree Elbow
1 x Wall Plate
4 x Fixing Screw
This kit provides the minimum materials. Extra lengths can be
added to the vertical and horizontal sections; see table 1 - 8".
Refer to Installation Instructions, Technical Specication on page 7
to identify when to use a restrictor.
Decide on the terminal position.
Measure the height from the finished hearth level/ base of the
appliance to the centre of the required hole.
A masonry installation requires the addition of a suitable lintel to
support the opening. Refer to Installation Instructions, Technical
Information for details of the flue length.
NOTE - Carefully consider:
a) Terminal positions
b) Flue supports
c) Weatherproofing
d) Fire precautions
For all the above options, you must conform to local and national
codes of practice.
Use only Gazco supplied flue on this appliance.
A guard (supplied) must be fitted to any terminal less than 2 metres
above any access such as level ground, a balcony or above a flat
roof.
TOP FLUE UP AND OUT WITH
ADDITIONAL BEND
Any additional bend may be used on the horizontal section (either
45° or 90°), but the overall horizontal ue run will be reduced.
When A = 1.0 to 1.499 metres B + C = 1.0 metres maximum
When A = 1.499 metres to 3.0 metres B + C = 4.0 metres maximum
EITHER 45˚