Reflex 105 Conventional Flue User Installation Manual
42
Servicing Instructions - Replacing Parts
15. Changing Between Gas Types
In order to change between gas types, it will be necessary to
change the following components:
Pilot
Main Injectors x 8
Crosslighting Injector
Gas Valve
Main Burner x 4
Contact your Gazco retailer for further information.
A kit of parts is available for this. Always quote the Model
number and Serial number when ordering any spare parts.
16. Debris Area Access
16.1 Remove the decorative front from the appliance by referring
to the separate instructions supplied with the front.
16.2 Remove the Glass Frame and the fuel bed components, see
Sections 2 and 3. Place carefully to one side.
16.3 Remove the Main Control Assembly, see Section 4.
16.4 Undo the 7 screws and remove the Debris Access hatch to
access the Debris Access Plate, see Diagram 39.
39
Screws
16.5 Undo the 7 screws to remove the Debris Access Plate,
see Diagram 40.
40
Screws
16.6 Clean out the debris.
16.7 Reassemble in reverse order.
17. Baffle
17.1 The Bafe must be removed before the Liners can be taken
out of the appliance.
BAFFLE
17.2 To do this undo the 5 screws securing it to the roof of the
rebox, see Diagram 41.
Screws
41
17.3 The Bafe can now be removed by lowering the front edge
and pulling forward through the front of the appliance.
TAKE CARE NOT TO DAMAGE THE SIDE PANELS.
17.4 When replacing the Bafe ensure that the 2 tabs t into the
slots either side of the rear liner bracket, see
Diagrams 42 & 43.
42
43