13. Fuel Bed Injectors
This appliance has 8 Fuel Bed Injectors.
NOTE: The injectors are not identical, see Diagram 34.
TO ENSURE CORRECT ASSEMBLY REPLACE EACH
INJECTOR INDIVIDUALLY.
34
13.1 Remove the Log Burners and Mesh Tray,
see Section 4.
13.2 Remove the 2 nuts and lock washers from each Burner
Bracket, see Diagram 35.
35
13.3 Remove the Gaskets, see Diagram 36.
36
Gasket
Servicing Instructions - Replacing Parts
13.4 Undo the Injectors individually and remove the bre washers
where tted, see Diagram 37.
NOTE: The far right injectors do not require washers.
37
13.5 Replace with the correct size Injector.
NOTE: DO NOT OVER TIGHTEN.
13.6 Repeat for the remaining Injectors.
13.7 Check for leaks.
13.8 Ret gaskets.
14. Latching Solenoid
14.1 Remove the Main Control Assembly, see Section 4.
14.2 Hold the brass adapter (large nut) with a 17mm spanner and
release the tube nut (small nut) from the adapter,
see Diagram 38.
38
Brass Adapter
Tube Nut
Tube Nut
14.3 Repeat on both sides of the Solenoid.
14.4 Remove the Solenoid plug from the Control Box,
see Diagram 38.
14.5 Cut the cable tie. Note the orientation of the cables.
14.6 Replace in reverse order.
Ensure that the cable ties are replaced.