Reflex 105 Conventional Flue User Installation Manual
40
Servicing Instructions - Replacing Parts
10.7 Remove the 2 screws securing the Valve to the support
bracket and withdraw the Valve.
10.8 Replace in reverse order and check for leaks.
11. Magnetic Safety Valve
11.1 Remove the Log Burners and Main Control Assembly,
see Section 4.
11.2 Remove the Gas Valve, see Section 10.
11.3 Undo the Thermocouple from the Interrupter Block and
remove the 2 Interrupter Leads.
11.4 Unscrew the Interrupter Block from the back of the Valve.
11.5 Undo the silver Magnetic Valve retaining nut on the back of
the Valve.
11.6 Gently tap out the Mag Valve.
11.7 Replace with a new unit.
11.8 Reassemble in reverse order ensuring that the interrupter
leads are connected correctly with the blue tag lead furthest
away from the gas valve body.
11.9 Check for leaks.
12. Control Box
12.1 To replace the Control Box first remove the Main Control
Assembly, see Section 4.
12.2 Release the cables from the clip on the underside of the
assembly.
12.3 Disconnect the Module and Solenoid leads from the Control
Box, see Diagram 32.
32
Module Lead
Solenoid Lead
*Other internal components removed for clarity
12.4 Pull the Control Box forward and remove the Ignition Lead.
The Control Box is held on by Velcro pads.
12.5 Remove the 2 screws to remove the 2 Interrupter Leads.
12.6 Remove the 8 way cable from the Control Box.
8 Way
Cable
Interrupter Leads
Ignition lead
LED Lead
33
Module
Lead
Solenoid
Lead
Thermocouple
Pilot Pipe
Control
Box
Module
Solenoid
12.7 Replace in reverse order.
After replacing the Control Box ensure that all cable
connections are refitted, see Diagram 33.
12.8 After replacing the Control Box you will need to reprogram
the handset.
— Press and hold the reset button on the control box until
you hear two signals. After the second longer signal:
— Release the reset button and within 20 seconds:
— Press the DOWN button on the handset until you hear
two additional short signals confirming the new code
is set. If there is a single long signal the code learning
sequence has failed or the wiring is incorrect.
Note: When pressing the DOWN button on the handset if two
beeps are not heard:
— Release the DOWN button and CONN will be displayed
on the handset screen. An 8 second count will
start on the handset screen followed by two short beeps
conrming the new code is set. If there is a single long
signal the code learning sequence has failed or the wiring
is incorrect.