Reflex 105 Conventional Flue User Installation Manual

39
Servicing Instructions - Replacing Parts
The Pilot Unit can now be serviced.
8.6 Remove the ignition lead from the electrode, see
Diagram 25.
8.7 Undo the thermocouple nut from the interrupter block at the
rear of the gas valve, see Diagram 27.
27
8.8 Lift the bracket away from the Main Control Assembly and
undo the 2 retaining screws, see Diagram 28.
28
8.9 Remove the Vidaex from the Thermocouple and ret to the
new Pilot Assembly.
8.10 When replacing the Pilot ensure the Thermocouple follows
its original route.
8.11 Set the spark gap, see Diagram 29.
29
15mm
4mm
9. Ignition Lead
9.1 Remove the Log Burners and Main Control Assembly,
see Section 4.
9.2 Disconnect the Ignition Lead from the Electrode, lift the
Control Box from the Velcro pads and pull forward to expose
the Ignition Lead and remove, see Diagram 30.
30
Ignition Lead
9.3 Replace with a new Ignition Lead following the original route.
Ret the Vidaex cover over the lead. Ensure the cover
engages fully over the Electrode.
9.4 Check the operation of the new Ignition Lead.
9.5 Reassemble in reverse order.
10. Gas Valve
To change the gas valve:
10.1 Remove the Log Burners and Main Control Assembly,
see Section 4.
10.2 Disconnect the Gas Inlet Pipe, see Diagram 31, Arrow A.
10.3 Disconnect the Gas Outlet Pipe, see Diagram 31, Arrow B.
10.4 Disconnect the Pilot Pipe, see Diagram 31, Arrow C.
10.5 Disconnect the Thermocouple, Thermocurrent Wires and the
Interrupter Block, see Diagram 31, Arrow D.
10.6 Remove the Eight Wire Loom, see Diagram 31, Arrow E.
There is an access hole in the top of the Control Bracket to
release the locking tab.
C
D
A
B
E
31
Screw
Screw