Reflex 105 Conventional Flue User Installation Manual
32
IGNITION FUNCTIONAL CHECK 1
PILOT WILL NOT LIGHT
Ensure there is no debris around the pilot assembly,
(e.g. soot, etc.) which could short the spark, clean the area.
Operate the valve
control system in the
manual mode via the
remote. Is there a
spark?
Consult User
Instructions and retry.
Ensure gap between the
electrode and thermocouple is
4.0mm and retry.
If gap is OK then rst change
the ignition lead and retry.
Check isolation tap and
gas meter, retry.
Correct and
retry.
Purge the gas pipes and
retry.
GO TO THE NEXT
CHART IGNITION
FUNCTIONAL CHECK 2
SYSTEM OK
There is a blockage in the system, check the inlet test point,
the mag seating and valve. Check thermocouple leads for correct
orientation, condition and connection
Is the gas turned on to the
appliance?
Is the gas pressure correct?
Has the system got
any air in it?
Does the pilot light?
Is the control being
operated correctly?
Will the pilot light
with a match?
No
Yes
No
Yes
No
Yes
Yes
No
No
Yes
No
No
Yes
Yes
Fault Finding Charts
Servicing Instructions