Reflex 105 Conventional Flue User Installation Manual
18
Installation Instructions
4.6 Place the Mains Lead to the side of the right hand bracket to
avoid damage, see Diagram 10.
10
Mains Lead
Plug
Bracket
4.7 Undo the 2 wing nuts, see Diagram 9.
4.8 Lift and slide the Main Control Assembly slightly to the
right and remove through the front of the appliance. Place
carefully to one side.
To install the gas supply:
4.9 Undo the screws to remove the metal plate from the back of
the appliance, see Diagram 11. This will need to be replaced
during installation.
11
Screws
Metal Plate
Gas Supply
4.10 The gas supply enters through the Silicone Panel located
on the left-hand rear of the outer box; this will need to be slit
with a sharp knife prior to passing the supply pipe through,
see Diagram 12.
12
Note: The Isolation Elbow needs to be attached to the gas
pipe before installation.
5. Masonry Chimney Installation
Carefully read the relevant section for the installation
method required.
5.1 This appliance is designed so that non-combustible board
can be taken right up to the edge of the ange.
NOTE: THE FLANGE EDGE HAS A DEPTH
OF 17MM. USE MATERIAL OF A SUITABLE
THICKNESS TO CREATE A FLUSH FINISH.
5a. Edge Finish Installation
5a.1 This method is designed so that non-combustible board can
be taken right up to the edge of the ange of the appliance.
5a.2 Fix the self adhesive foam seal around the back of the xing
ange of the appliance.
5a.3 Prepare the ue connection using the chosen method
described in Section 2.
5a.4 Connect the ue and install the appliance into the aperture.
At the same time ensure that the gas pipe passes through
the silicon panel at the back of the appliance.
Provide electric services into the void on the right hand
side.
It is necessary to be able to disconnect the
appliance from the mains electrical supply after
installation.
This may be achieved by an accessible plug or by
incorporating a switch into the fixed wiring in
accordance with the rules in force.
5a.5 Slide the metal plate, previously removed, over the gas pipe
and secure with a screw, see Diagram 13.
13
Screws
Metal Plate
Gas Supply