Reflex 105 Conventional Flue User Installation Manual
17
Installation Instructions
2.9 If a exible liner is to be used check the seal on the inner lip
of the spigot plate is intact. Replace if necessary.
3
Options 3 and 4 (Studwork with Edge nish or decorative
front) must be tted using the top exit only with rigid twin
wall ue pipe.
3. Removing the Glass Frame
3.1 Remove the glass door by removing the 2 side trims, see
Diagram 4. These are held on by magnets.
4
3.2 Lift out the bottom slotted trim, see Diagram 5.
5
3.3 Remove the 2 screws at the base of the door, see Diagram 6.
6
Screws
3.4 Pull up the handle at the front, see Diagram 6.
3.5 Whilst supporting the top, lift the door using the handle, up
and over the lower edge, see Diagram 7.
7
3.6 Remove the 2 boxes from the appliance and store safely as
they contain the Log Burners and fuel effects.
4. Removing the Main Control Assembly
The Main Control Assembly will need to be removed to
install the gas supply.
4.1 Remove the 3 screws from the front of the Mesh Tray,
see Diagram 8.
8
Rear Screws
Front Screws
4.2 Remove the 3 screws at the rear of the Mesh Tray, see
Diagram 8.
4.3 Slide the Mesh Tray forward slightly and carefully lift over
the Log Burner Brackets, Pilot and Cross Lighter.
4.4 Remove through the front of the appliance.
4.5 Disconnect the Mains Lead Plug from the Module, see
Diagram 9.
DO NOT REMOVE THE WIRES FROM THE PLUG.
9
Mains Lead Plug
2 Wing Nuts